Scroll Top

ENERGY CABLES

Product Range

450/750 V CU/PVC
Single core up to 1000 mm² / Single core up to 50 mm²

Solid or Stranded Circular or Flexible Copper Conductor Class 1 or Class 2 or Class 5 respectively & Polyvinyl Chloride Insulation.

Standard: BS EN 50525-2-31
                 IEC 60227
                 BS 6004

BASEC Approved

450/750 V CU/LSHF
Single core up to 1000 mm² / Single core up to 50 mm²

Solid or Stranded Circular or Flexible Copper Conductor Class 1 or Class 2 or Class 5 respectively & Low Smoke Halogen Free Insulation.

Standard: BS EN 50525-3-41
                 BS 7211

BASEC Approved

0.6/1 kV CU/XLPE/AWA/PVC or CU/XLPE/PVC
Single core up to 1000 mm²

Stranded Circular Copper Conductor Class 2, Cross Linked Polyethylene Insulation , Polyvinyl Chloride Bedding, (with or without), Aluminium Wire Armour & Polyvinyl Chloride Outer Sheath.

Standard: IEC 60502-1
                 BS 5467

BASEC Approved

0.6/1 kV CU/XLPE/SWA/PVC or CU/XLPE/PVC
2,3,4,5 cores up to 500 mm²

Stranded Circular or Sector Shaped Copper Conductor Class2, Cross Linked Polyethylene Insulation, Polyvinyl Chloride Bedding, (with or without), Galvanized Steel Wire Armour & Polyvinyl Chloride Outer Sheath.

Standard: IEC 60502-1
                 BS 5467

BASEC Approved

Core colours as per BS can be given

0.6/1 kV CU/XLPE/AWA/LSHF or CU/XLPE/LSHF
Single core up to 1000 mm²

Stranded Circular Copper Conductor Class 2, Cross Linked Polyethylene Insulation, Low Smoke Halogen Free Bedding,(with or without), Aluminium Wire Armour & Low Smoke Halogen Free Outer Sheath.

Standard: IEC 60502-1
                 BS 6724

0.6/1 kV CU/XLPE/SWA/LSHF or CU/XLPE/LSHF
2,3,4,5 cores up to 500 mm²

Stranded Circular or Sector Shaped Copper Conductor Class2, Cross Linked Polyethylene Insulation, Low Smoke Halogen Free Bedding, (with or without), Galvanized Steel Wire Armour & Low Smoke Halogen Free Outer Sheath.

Standard: IEC 60502-1
                 BS 6724

BASEC Approved

Core colours as per BS can be given

3.6/6 kV up to 19/33 kV CU/XLPE/AWA/PVC
Single core up to 1000 mm²

Stranded Circular Compacted Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, Copper Wire and/ or Copper & Tape Screen, Polyvinyl Chloride Bedding, Aluminium Wire Armour Polyvinyl Chloride Outer Sheath.

Standard: IEC 60502-2
                 BS 6622

(Other outer sheath like MDPE / HDPE can be offered upon request)

3.6/6 kV up to 19/33 kV CU/XLPE/SWA/PVC
3 cores up to 400 mm²

Stranded Circular Compacted Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, Copper Wire and/or Copper Tape Screen, Non-Hygroscopic Filler and Tape, Polyvinyl Chloride Bedding, Galvanized Steel Wire Armour & Polyvinyl Chloride Outer Sheath.

Standard: EC 60502-2
                 BS 6622

(Other outer sheath like MDPE / HDPE can be offered upon request)

3.6/6 kV up to 19/33 kV CU/XLPE/SWA/LSHF
3 cores up to 400 mm²

Stranded Circular Compacted Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, Copper Wire and/or Copper Tape Screen, Non-Hygroscopic Filler and Tape, Low Smoke Halogen Free, Galvanized Steel Wire Armour & Low Smoke Halogen Free Outer Sheath.

Standard: IEC 60502-2

38/66 kV up to 127/220 kV CU/XLPE/CWA/LEADHDPE
Single core up to 2500 mm²

Stranded Circular Compacted or Segmental (Milliken)Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, Copper Wire and Copper Tape Screen, and/or Lead Sheath & High Density Polyethylene Sheath with Graphite Coating.

Standard: IEC 60840
                IEC 62067

300/500 V CU/PVC/PVC (70 or 90 degrees)
2,3,4,5 cores up to 25mm²

3182/3/4/5 Y (circular) / H05VV-F 2/3/4/5
3092/3/4/5 Y (circular) / H05V2V2-F 2/3/4/5

Flexible Stranded Copper Conductor Class 5, Polyvinyl Chloride Insulation & Polyvinyl Chloride Sheath.

Standard: BS EN 50525-2-11
                 IEC 60227
                 BS6004
                 BS6500

0.6/1 kV CU/XLPE/SWA/PVC
2 cores up to 61 cores up to 6 mm²

Solid or Stranded Copper Conductor Class 1 and Class 2 respectively, Cross Linked Polyethylene Insulation, Polyvinyl Chloride Bedding, Galvanized Steel Wire Armour & Polyvinyl Chloride Outer Sheath.

Standard: IEC 60502-1
                 BS 5467

3.6/6 kV up to 8.7/15 kV CU/XLPE/HDPE
Single core up to 500 mm²

Stranded Circular Compacted Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, HDPE as an Outer Sheath with Graphite Coating Layer.

Standard: IEC 60502-2
                 BS 6622

3.6/6 kV up to 8.7/15 kV CU/XLPE/CW/HDPE
Single core up to 500 mm²

Inner Conductor consist Stranded Circular Compacted Copper Conductor Class 2, Inner Semi Conductive Compound, Cross Linked Polyethylene Insulation, Outer Semi Conductive Compound, Outer Conductor consist of Annealed Copper Wires applied over the Inner Insulation in a layer or two to maintain same CSA of inner conductor and HDPE as an Outer Sheath with Graphite Coating Layer.

Standard: IEC 60502-2
                 BS 6622